    户外预装式变电站(欧式)概述 Overview

    本产品是吸收国外技术,结合国内实际情况研制开发的,整台产品具有体积小、安装维护简便、低噪音、低损耗、防盗、过负荷能力强、全保护等特点。适用于新建小区、绿化带、公园、车站宾馆、工地、机场等场所。

    系列美式预装式箱式变电站, 适用于10kV环网供电,双电源供电或终端供电系统中,作为变电、计量、补偿控制和保护装置。

    本产品符合下列标准:GB T17467 1998《高压低压预装式变电站》、DL/T537-93《6-35KV箱式变电站订货技术条件》

    This product is developed by absorbing the latest advanced technology from abroad and combining with the actual situation in China. The whole product has the characteristics of small size, simple installation and maintenance, low noise, low loss, anti-theft, strong overload ability and full protection. It is suitable for new residential areas, green belts, parks, stations, hotels, construction sites, airports and other places.

    A series of American prefabricated box substations are suitable for 10kV ring network power supply, dual power supply or terminal power supply systems, as substation, metering, compensation control and protection devices.

    This product meets the following standards: GB T17467 1998 "High Voltage and Low Voltage Pre-installed Substation" and DL/T537-93 "Technical Conditions for Order of 6-35KV Box Substation"

    户外预装式变电站(欧式)型号含义 Type meaning

    户外预装式变电站(欧式)型号含义

    户外预装式变电站(欧式)正常使用条件 Normal use condition

    ◆海拔高度不超过1000m;

    ◆环境温度:-35℃~+40℃;

    ◆相对湿度:日平均值不大于95%,月平均值不大于90%;

    ◆安装场所:无火灾、爆炸危险、化学腐蚀性气体及通风良好的场所,倾斜角度不大于3°。

    ◆Elevation not exceeding 1000m;

    ◆Environmental temperature: - 35 ~40 ~C;

    ◆Relative humidity: the daily average is not more than 95%, and the monthly average is not more than 90%.

    ◆Installation site: No fire, explosion danger, chemical corrosive gas and well ventilated place, inclination angle is not more than 3 degrees.

    户外预装式变电站(欧式)功能及特点 Functions and characteristics

    ◆全绝缘、全密封、免少维护、可靠保证人身安全;

    ◆结构紧凑、体积仅为同容量欧变1/3-1/5的高度低;

    ◆可采用分箱式结构,避免变压器油箱内油的污染;

    ◆高压侧采用双熔丝全范围保护,大大降低成本:

    ◆既可用于环网,也可用于终端,电缆头可在200A负荷电流时紧急插拔;

    ◆箱体采用蜂窝式双夹层复合板,隔温又散热的功能;

    ◆低压侧加装电子缺相保护器,当系统内出现不正常电压时,可快速分断主进开关;

    ◆高压侧油浸式负荷开关或SF6负荷开关, 可电动升级, 为实现配网自动化打下基础。

    ◆采用油浸式或性能更优的SF11系列变压器。

    ◆Fully insulated, fully sealed, less maintenance, reliable guarantee of personal safety;

    ◆compact structure, volume is only 1/3-1/5 of the same capacity Euclidean height is low;

    ◆Sub-box structure can be adopted to avoid oil pollution in transformer tank.

    ◆High voltage side adopts full range protection with double fuses, which greatly reduces the cost.

    ◆It can be used not only in loop network, but also in terminal. The cable head can be plugged in and out in case of 200A load current.

    ◆The box body adopts honeycomb double sandwich composite board, which has the functions of heat insulation and heat dissipation.

    ◆The low voltage side is equipped with an electronic phase-gap protector. When abnormal voltage occurs in the system, the main switch can be quickly interrupted.

    ◆High-voltage side oil-immersed load switch or SF6 load switch can be upgraded electronically, laying the foundation for realizing distribution automation.

    ◆Use oil-immersed or better performance SF11 series transformer.

    户外预装式变电站(欧式)主要技术参数 The main technical parameters

    户外预装式变电站(欧式)主要技术参数

    户外预装式变电站(欧式)电缆进出线土建图(YB25)  Civil Drawing of Cable Inlet and Outlet Line in Substation (YB25)

    技术要求:

    ◆有关尺寸参见组合变实际尺寸:

    ◆混凝土台基应表面平整,组合变电站采用压板固定的方式固定在台基上;

    ◆接地排和电缆固定支架的型式可根据实际情况而定;

    ◆电缆固定架和接地排应预埋;

    ◆进出线电缆孔的位置根据具体情况而定;

    ◆组合变安装后开关正面必须有不小于1.5m的空隙,以利操作;

    ◆接地网可用12镀锌圆钢或40×4镀锌扁铜制作,接地电阻应符合电力部门要求。

    Technical requirements:

    ◆Refer to the combination of different actual sizes for relevant sizes.

    ◆The surface of concrete bench should be flat, and the combined substation should be fixed on the bench by pressing plate.

    ◆The type of grounding row and cable fixing bracket can be determined according to the actual situation.

    ◆Cable fixtures and ground platforms should be embedded in advance.

    ◆The location of the cable holes in and out wires depends on the specific situation.

    ◆The front of the switch must have no clearance less than 1.5m after the installation of the combined transformer, so as to facilitate operation.

    ◆Grounding grid can be made of 12 galvanized round steel or 40 *4 galvanized flat copper. Grounding resistance should meet the requirements of power department.